Style 1. Die Sets for SN Series Crimper
Jaw Part.No | Capacity/AWG | Craft | Application | If Exchangeable | |
![]() |
28B | 0.1-1.0mm2 / AWG28-18 | EDM | Non-Insulated Terminals | Y |
![]() |
48B | 0.14-1.5mm2 / AWG26-16 | CAST | Non-Insulated Terminals | Y |
![]() |
02C | 0.25-2.5mm2 / AWG24-20 | CAST | Insulated Terminals | Y |
![]() |
2549 | 0.08-0.5/0.25/0.5/1.0mm2 / AWG28-18 | EDM | Non-Insulated Terminals | Y |
![]() |
2546B | 2.5/4/6.0mm2/ AWG13-10 | EDM | Solar PV Connectors | Y |
![]() |
01BM | 0.08-0.5mm2 / AWG28-20 | EDM | Non-Insulated Terminals | N |
![]() |
06 | 0.5-6.0mm2 / AWG20-10 | CAST | Non-Insulated Terminals | Y |
![]() |
0325 | 0.5-2.5mm2 / AWG20-13 | CAST | Non-Insulated Terminals | Y |
![]() |
02WF2C | 0.5-2.5mm2 / AWG20-13 | CAST | Insulated Terminals and Cable End-sleeves | Y |
![]() |
06WF | 0.25-6.0mm2 / AWG24-10 | CAST | Insulated and Non-Insulated Cable End-sleeves | Y |
Style 2. Die Sets for LY Series Crimper
Jaw Part.No | Capacity/AWG | Craft | Application | If Exchangeable | |
![]() |
30J | 0.5-6.0mm2 / AWG22-10 | CAST | For cable end-sleeves and insulated terminals | Y |
![]() |
05FL | 4.8-6.3mm2 | EDM | For flag type receptacles | Y |
![]() |
101 | 1.5-10mm2 / AWG16-8 | CAST | For non-insulated terminals | Y |
![]() |
1016 | 0.5-16mm2 / AWG20-8 | CAST | For non-insulated terminals | Y |
![]() |
04WF | 1-6.0mm2 / AWG20-10 | CAST | For insulated and non-insulated cable end-sleeves | Y |
![]() |
35WF | 10-35mm2 / AWG8-2 | CAST | For insulated and non-insulated cable end-sleeves | Y |
![]() |
2048 | Max.Dia 8.5mm | CAST | For Spark Plug Terminals | N |
Style 3. Die Sets for HS Series Crimper
Jaw Part.No | Capacity/AWG | Craft | Application | If Exchangeable | |
![]() |
30J | 0.5-6.0mm2 / AWG22-10 | CAST | For cable end-sleeves and insulated terminals | Y |
![]() |
05FL | 4.8-6.3mm2 | EDM | For flag type receptacles | Y |
![]() |
101 | 1.5-10mm2 / AWG16-8 | CAST | For non-insulated terminals | Y |
![]() |
1016 | 0.5-16mm2 / AWG20-8 | CAST | For non-insulated terminals | Y |
![]() |
04WF | 1-6.0mm2 / AWG20-10 | CAST | For insulated and non-insulated cable end-sleeves | Y |
![]() |
35WF | 10-35mm2 / AWG8-2 | CAST | For insulated and non-insulated cable end-sleeves | Y |
Style 4. Die Sets for AP Series Crimper
Can i use 28b or 48b dies with hs30j ap crimper?
No. 28B and 48b are for JN series crimpeR – see chart above for dies for hs series